Military Vehicle Rain Performance Test System

Mediaș, Romania

A controlled severe-rain simulation system engineered to verify the sealing performance of military vehicles.

Military vehicle rain performance test chamber with adjustable spray nozzles in Mediaș, Romania
ApplicationMilitary vehicle leak testing
Spray system140 adjustable nozzles
Water pressure1–6 bar
Water storage18-ton recirculation tank

Customer requirement

Reproduce severe rain under controlled, repeatable conditions.

The customer needed to test the sealing performance of military vehicles under intense simulated rainfall. The system had to direct water at selected vehicle zones, maintain the required pressure for a defined period and record the complete test data.

Water filtration and recirculation equipment for the military vehicle rain test system

Our solution

Targeted rain simulation with closed-loop water recovery.

Atlas engineered an enclosed test room with 140 adjustable nozzles distributed around the vehicle. Operators set test pressure and duration from the PLC interface, while the system records the operating data. An 18-ton tank filters and recirculates the process water for continuous reuse.

  • 140 adjustable spray nozzles
  • Targeted rainfall on selected vehicle areas
  • Adjustable operating pressure from 1 to 6 bar
  • PLC-controlled test duration and water pressure
  • Automatic recording of test data
  • 18-ton filtered water recirculation tank

Technical configuration

Controlled pressure, documented results and efficient water use.

The spray, control and recovery systems work together as one repeatable testing process.

01

Spray coverage

140 adjustable nozzles direct simulated rainfall toward the vehicle zones required for each test.

02

Pressure & duration

Operators define the test pressure between 1 and 6 bar and set the operating time from the PLC screen.

03

Test records

Operating data is recorded to support consistent testing and review of each completed cycle.

04

Water recirculation

The 18-ton tank and filtration circuit recover the water and return it to the spray system for continuous reuse.

Atlas project scope

Atlas engineered an enclosed test room with 140 adjustable nozzles distributed around the vehicle.

Planning a special-purpose test system?

Send us your vehicle dimensions, test pressure and validation process.

Request a project proposal ↗
← All projects← Back to industrial paint shops