+359 87 82 48 950WhatsApp ↗Viber ↗

Preparation Stations

Filtered preparation areas for sanding, spot repair, priming and finishing operations.

Request a project proposal ↗
Vehicle preparation stations installed in a workshop

Engineered for your process

Prepare every surface in a cleaner, more controlled work area.

Quality finishing begins with proper preparation. Our preparation stations provide the controlled environment needed for sanding, masking, small repairs and primer application.

Available in full down-draft and semi-down-draft airflow configurations, each station can be designed with single-fan or double-fan extraction to suit the workshop layout and repair process.

Controlled extraction

Filtered air handling helps keep dust and overspray away from the preparation process.

Flexible work area

Front and side PVC curtains create an adaptable bay for vehicle preparation and spot repair.

Workshop integration

Lighting, floor configuration and airflow can be selected around the required workflow.

Technical configuration

Preparation stations configured for efficient body-shop flow.

Two standard station sizes cover common automobile and light-commercial preparation requirements. Dimensions and equipment can be adapted to the site and the required process.

STANDARD RANGE

Preparation station models

Both models use front and side PVC curtains, LED lighting and EU3/EU5 filtration. The double-fan configuration adds dedicated exhaust capacity and a grated preparation floor.

Technical specificationPREP 6000
Single fan
PREP 7000
Double fan
Internal dimensions6200 (L) × 3626 (W) × 2770 (H) mm7200 (L) × 3626 (W) × 2800 (H) mm
External dimensions7600 (L) × 3626 (W) × 3070 (H) mm8600 (L) × 3626 (W) × 3400 (H) mm
Entrance doorFront curtainsFront curtains
Side closureSide PVC curtainsSide PVC curtains
Service door——
Top lighting24 × 16 W LED24 × 16 W LED
Fresh-air fan motor10 HP (7.5 kW)7.5 HP (5.5 kW)
Fresh-air flow24,000 m³/h18,000 m³/h
Burner / heat exchangerNoNo
Exhaust fan motor—10 HP (7.5 kW)
Exhaust airflow—24,000 m³/h
Floor filter / ceiling filterEU3 / EU5EU3 / EU5
Floor configurationStandard floor2 lines of grates + 3 lines of closed plates
Maximum weightMaximum floor load500 kg / tyre
Metal basement—300 mm
Maximum electric power9 kW15 kW
Panel / command380 V / On–Off380 V / On–Off

Technical values shown are for the standard range. Final configuration is determined by the selected airflow layout and site requirements.

Configuration choices

Specify the preparation area around your workflow.

01

Airflow layout

  • Full down-draft or semi-down-draft configuration
  • Single-fan or double-fan design
  • Fresh-air and dedicated exhaust arrangements
02

Work area

  • Front and side PVC curtain enclosures
  • Station lengths for cars, vans and light commercial vehicles
  • Floor layout selected around the repair process
03

Site integration

  • LED lighting and filtration package
  • Electrical panel matched to the installation
  • Layout coordinated with the surrounding paint-shop equipment

Related systems

Build the right system configuration.

Send us the product dimensions, capacity and painting process.

Request a project proposal ↗